Preview

The Clinician

Advanced search

CURRENT METHODS OF AMBULATORY ELECTROCARDIOGRAM MONITORING. TECHNICAL ASPECTS

https://doi.org/10.17650/1818-8338-2016-10-4-16-28

Abstract

The review considers the main characteristics and diagnostic capabilities of current noninvasive and invasive methods of ambulatory electrocardiogram monitoring used in diagnosis of cardiac rhythm and conduction disturbances. Strength and weaknesses of different methods of long-term electrocardiogram monitoring are discussed.

About the Author

E. V. Pervova
Moscow City Clinical Hospital No. 4, Moscow Healthcare Department; Federal Almazov North-Western Medical Research Center
Russian Federation

Department of Surgical Treatment of Complex Cardiac Rhythm Disorders and Cardiac Pacing; Research Laboratory Electrocardiology Research Department of Clinical Physiology of Circulation, Institute of Heart and Vessels.

25 Pavlovskaya St., Moscow 115093; 2 Akkuratova St., Saint Petersburg 197341



References

1. Crawford M.H., Bernstein S.J., Deedwania P.C. et al. ACC/AHA Guidelines for Ambulatory Electrocardiography. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Revise the Guidelines for Ambulatory Electrocardiography). Developed in collaboration with the North American Society for Pacing and Electrophysiology. J Am Col Cardiol 1999;34(3):912–48.

2. National Russian guidelines on application of the methods of Holter monitoring in clinical practice. Rossiyskiy kardiologicheskiy zhurnal = Russian Journal of Cardiology. 2014;2(106):6–71. (In Russ.).

3. Holter N.J. New method for heart studies: сontinuous electrocardiography of active subjects over long periods is now practical. Science 1961;134(3486):1214–20.

4. Fung E., Järvelin M.R., Doshi R.N. et al. Electrocardiographic patch devices and contemporary wireless cardiac monitoring. Front Physiol 2015;6:149. DOI: 10.3389/fphys. 2015.00149.

5. Raviele A., Giada F., Bergfeldt L. et al. Management of patients with palpitations: A position paper from the European Heart Rhythm Association. Europace 2011;13(7):920–34. DOI: 10.1093/europace/eur130.

6. Task Force for the Diagnosis and Management of Syncope; European Society of Cardiology (ESC); European Heart Rhythm Association (EHRA); Heart Failure Association (HFA) et al. Guidelines for the diagnosis and management of syncope (version 2009). Eur Heart J 2009;30(21):2631–71. DOI: 10.1093/eurheartj/ehp298.

7. Kligfield P., Gettes L.S., Bailey J.J. et al. Recommendations for the standardization and interpretation of the electro-cardiogram: part I: The electrocardiogram and its technology: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: endorsed by the International Society for Computerized Electrocardiology. Circulation 2007;115(10):1306–24. DOI: 10.1161/CIRCULATIONAHA.106.180200. PMID: 17322457.

8. The user’s manual. A set of wearable monitors computerized daily monitoring of ECG, BP, SP. KMkn – “Union” – “LCA”. Job description with the monitor. Moscow: LCA Advanced technology, 2008. (In Russ.).

9. Homaeinezhada M.R., Ghaffari A., Najjaran Toosi H. et al. Ambulatory Holter ECG individual events delineation via segmentation of a wavelet-based information-optimized 1-D feature. Scientia Iranica 2011;18(1):86–104.

10. Pervova E.V. Modern pacing on Holter ECG monitor: a practical guide. Moscow: Medika, 2011. 368 p. (In Russ.).

11. Balady G.J., Bufalino V.J., Gulati M. et al. COCATS 4 Task Force 3: Training in Electrocardiography, Ambulatory Electrocardiography, and Exercise Testing. J Am Coll Cardiol 2015;65(17):1763–77. DOI: 10.1016/j.jacc.2015.03.021.

12. Mittal S., Movsowitz C., Steinberg J.S. Ambulatory external electrocardiographic monitoring: focus on atrial fibrillation. J Am Coll Cardiol 2011;58(17):1741–9. DOI: 10.1016/j.jacc.2011.07.026.

13. Saadi D.B., Sørensen H.B. D., Hansen I.H., et al. ePatch® – A Clinical Overview: DTU Orbit – The Research Information System proposals. Annual report year: 2014. Available at: http://orbit.dtu.dk/en/publications/epatcha-clinical-overview (5a3e37a2-76a8-4240-aae6-781269a8ca2a)/export.html.

14. Tung C.E., Su D., Turakhia M.P., Lansberg M.G. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA. Front Neurol 2015;5:266. DOI: 10.3389/fneur.2014.00266.

15. Barrett P.M., Komatireddy R., Haaser S. et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am J Med 2014;127(1);95:e11–7. DOI: 10.1016/j.amjmed 2013.10.003.

16. Pérez-Rodon J., Francisco-Pascual J., Rivas-Gándara N. et al. Cryptogenic Stroke and Role of Loop Recorder. J Atr Fibrillation 2014;7(4):29–35. DOI: https://doaj.org/article/9cdd95eae7514d70b57a559d6df530c1.

17. Reiffel J.A., Schwarzberg R., Murry M. Comparison of autotriggered memory loop recorders versus standard loop recorders versus standard loop recorders versus 24-hour Holter monitors for arrhythmia detection. Am J Cardiol 2005;95(9):1055–9. DOI: 10.1016/j.amjcard.2005.01.025. PMID: 15842970.

18. Brignole M., Alboni P., Benditt D. et al. Guidelines on management (diagnosis and treatment) of syncope. Eur Heart J 2001;22(15):1256–306. DOI: 10.1053/euhj.2001.2739. PMID: 11465961.

19. Brignole M., Alboni P., Benditt D.G. et al. Guidelines on management (diagnosis and treatment) of syncope – update 2004. Europace 2004;6(6):467–537. DOI: 10.1016/j.eupc.2004.08.008. PMID: 15519256.

20. Mittal S., Yang E.H., Joshi R. et al. Implantable Loop Recorder: The Heart. org Medscape Drugs and Diseases proposals. Available at: http://emedicine.medscape.com/article/1920236-overview#showall.

21. Shanmugam N., Liew R. The implantable loop recorder-an important addition to the armentarium in the management of unexplained syncope. Ann Acad Med Singapore 2012;41(3):115–24. PMID: 22538738.

22. Krahn A.D., Klein G.J., Yee R. et al. Use of an extended monitoring strategy in patients with problematic syncope. Reveal Investigators. Circulation 1999; 99(3):406–10. PMID: 9918528.

23. Brignole M., Sutton R., Menozzi C. et al. Early application of an implantable loop recorder allows effective specific therapy in patients with recurrent suspected neurally mediated syncope. Eur Heart J 2006;27(9):1085–92. DOI: 10.1093/eurheartj/ehi842. PMID: 16569653.

24. Reveal XT programmable parameters. In: REVEAL® XT 9529. Insertable Cardiac Monitor. Clinician Manual. Minneapolis: Medtronic Inc., 2007.

25. Monitor Settings. In: Monitoring Devices Merlin™ Patient Care System. Help Manual For the following devices: SJM Confirm™ Implantable Cardiac Monitor. Sylmar: St. Jude Medical Cardiac Rhythm Management Division, 2008.

26. Ng E., Stafford P.J., Ng G.A. Arrhythmia detection by patient and auto-activation in implantable loop recorders. J Interv Card Electrophysiol 2004;10(2):147–52. DOI: 10.1023/B:JICE.0000019268.95018.91. PMID: 15014215.

27. Hindricks G., Pokushalov E., Urban L. et al. Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trial. Circ Arrhythm Electrophysiol 2010;3(2):141–7. DOI: 10.1161/CIRCEP.109.877852.

28. Sanna T., Diener H.C., Passman R.S. et al. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med 2014;370(26):2478–86. DOI: 10.1056/NEJMoa1313600.

29. MRI procedure. REVEAL® XT 9529. Insertable Cardiac Monitor. Clinician Manual. Minneapolis: Medtronic, 2007.

30. SJM Confirm™. Model DM2100. Implantable Cardiac Monitor. Model DM2102. Implantable Cardiac Monitor with AF Detection. Use’s Manual. Sylmar: St. Jude Medical, Cardiac Rhythm Management Division, 2008.

31. Farwell D.J., Freemantle N., Sulke N. The clinical impact of implantable loop recorders in patients with syncope. Eur Heart J 2006;27(3):351–6. DOI: 10.1093/eurheartj/ehi602. PMID: 16314338.

32. Tikhonenko V.M., Popov S.V., Tsurinova E.A., Treshkur T.V. Long-term ECG monitoring with telemetry: a novel technique of diagnosis of rare symptomatic arrhythmias and syncope. Vestnik aritmologii = Journal of Arrhythmology 2013;(73):58–62. (In Russ.).

33. CardioNet, Inc. Enters Into Agreement with United Healthcare Insurance Company Provides Coverage for CardioNet MCOTTM: Business Wire.com proposals. Available at: http://www.businesswire.com/news/home/20130610006443/en/CardioNet-Enters-Agreement-UnitedHealthcare-Insurance-Company.


Review

For citations:


Pervova E.V. CURRENT METHODS OF AMBULATORY ELECTROCARDIOGRAM MONITORING. TECHNICAL ASPECTS. The Clinician. 2017;11(1):16-28. (In Russ.) https://doi.org/10.17650/1818-8338-2016-10-4-16-28

Views: 1359


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1818-8338 (Print)